(e) Width, length (W, L) : Bytes E to 11, 12 to 15
Specifies here are the width and length of the window, in units of 1/1200
inches. If the W or L value is outside the maximum scan area of this
scanner, the following error information is returned:
f Status: B©00001π (CHECK CONDITION)
f Sense key: X©5π (ILLEGAL REQUEST)
The same error is also returned if this scanner is set to less than one raster
line for vertical scanning or to less than two bytes for horizontal scanning.
Notes:
1. ULX, ULY, W, L versus maximum scan area:
0 < (ULX + W) e 14592 (in 1/1200 inches)
0 < (ULY + L) e 20736 (in 1/1200 inches)
2. Conditions for horizontal scanning:
9 e [XR ¥ W/1200] e 4864 (dot)
(Values under 0 in [ ] are omitted.)
3. Conditions for vertical scanning:
1 e [YR ¥ L/1200] e 6912 (line)
(Values under 0 in [ ] are omitted.)
4. Conditions for horizontal and vertical scanning (in 1/1200 inches):
13200 (11∫) < (ULX + W) e 14592
When this condition is satisfied, following condition must also be
satisfied (only for CMPII option equipped).
0 < (ULY + L) e 19842 (A3 length)
4 $ 42