(5) Messages
The following messages are supported by this scanner:
f ABORT
f BUS DEVICE RESET
f COMMAND COMPLETE
f DISCONNECT
f IDENTIFY
f INITIATOR DETECTED ERROR
f MESSAGE PARITY ERROR
f MESSAGE REJECT
f NO OPERATION
f RESTORE POINTERS
f SAVE DATA POINTER
(6) Others
The bits and fields for which the word ™Reserved∫ is described are checked. For a
non>zero, an error is returned.
4.1 Physical Specifications
The devices linked to this interface are daisy>chained with each other. A
terminator is attached to the ends of the interface. Interface specifications are
shown below.
(1) Connection
Terminator
SCSI device SCSI device SCSI device
Terminator
Note:
Use shielded interface cable to avoid unintentional errors.
4 $ 3