Fujitsu M3097G Photo Scanner User Manual


 
a. Transfer data type: Byte 2
Specifies the type of data to be transferred between the initiator and target.
This scanner supports X©02π (dither pattern) and X©03π (d pattern). If any other
value is specified, this scanner returns the following error information:
f Status: B©00001π (CHECK CONDITION)
f Sense key: X©5π (ILLEGAL REQUEST)
b. Transfer identification: Byte 4 to 5
Identifies each data. On this scanner, this field is used to differentiate with a
value from 0 to 4 downloadable dither patterns. If a value 5 or larger is
specified, this scanner returns the following error information:
f Status: B©00001π (CHECK CONDITION)
f Sense key: X©5π (ILLEGAL REQUEST)
c. Transfer length (TL) : Bytes 6 to 8
Specifies the bytes of data to be transferred by the initiator.
If TL = 0, no data is transferred. This is not regarded as an error.
If TL > 1034 (larger than a dither pattern of 32 ¥ 32), this scanner returns the
following error information:
f Status: B©00001π (CHECK CONDITION)
f Sense key: X©5π (ILLEGAL REQUEST)
4 $ 69