j. Command>specific information bytes: Bytes 8 to B
On this scanner, this field is not supported and is fixed to X©00000000π.
k. Additional sense code, additional sense code qualifier: Bytes C and D
A combination of these fields specifies detailed information about the error
reported in the sense key. This scanner reports the following information:
Sense
key
Additional
sense code
Additional
sense code
qualifier
Description
0 00 00 No> sense
2 00 00 Not ready
2 80 01 Interlock switch is opened
3 80 01 Jam
3 80 02 ADF cover open
3 80 03 Document chuter empty of paper
3 80 04 Detects job separation sheet
(See Appendix A.5)
4 80 01 Blown fuse for FB motor
4 80 02 Blown fuse for heater
4 80 03 Blown lamp fuse
4 80 04 Blown fuse for ADF motor
4 80 05 Mechanical alarm
4 80 06 Optical alarm
4 44 00 Abnormal internal target
4 47 00 SCSI parity error
5 20 00 Invalid command
5 24 00 Invalid field in CDB
5 25 00 Unsupported logical unit
5 26 00 Invalid field in parameter list
5 2C 02 Wrong window combination
6 00 00 UNIT ATTENTION
B 43 00 Message error
B 80 01 Image transfer error
4 $ 33