C156-E097-01EN 2 - 5
2.1.3 Environmental and power requirements
Table 2.3 lists the environmental and power requirements.
Table 2.3 Environmental and power requirements (1 of 2)
Item Specification
Power
requirements
Average +5 VDC±5%, 1.1 A (2.5 A Max., excluded for
terminating resistor) (*1)
Ready 3.9 W (*2)
Random seek, read, or write
(*2)
4.9 W (TYP) (*2)
Power save 0.5 W (MIN) (*2)
With panel
101.6×150.0×25.4 mm
Without panel
101.6×148.4×25.4 mm
Weight 470 g (with panel)
Environmental
requirements
Operating Temperature: 5 to 45°C (*3)
(gradient 15°C /h or less)
Relative humidity: 10 to 85% (Noncondensing)
Max. wet bulb temperature: 29°C or lower
Idle Temperature: 0 to 50°C
Relative humidity: 10 to 85% (Noncondensing)
Max. wet bulb temperature: 36°C or lower
Transport Temperature: –40 to 60°C (24 hours or less)
Temperature: –20 to 60°C (24 hours or more)
Relative humidity: 5 to 90% (Noncondensing)
Max. wet bulb temperature: 41°C or lower
Requirement: Packing conditions specified by Fujitsu
Installation Tilt angle –5° to +10°
Vibration/
shock
Operating 0.4 G (5 to 500 Hz, sine sweep)
Shock 2 G (10ms, half-sine pulse)
Idle
No cartridge, power ON
1.0 G (5 to 500 Hz, sine sweep)
Shock 5 G (10 ms, half-sine pulse)
Transport Shock 50 G (10 ms, half-sine pulse)
Requirement: Packing conditions specified by Fujitsu
Altitude Operating 3,000 m (10,000 ft) or less
Idle 12,000 m (40,000 ft) or less
Power
consumption
Dimensions
(W×D×H)