Fujitsu MCF3064SS Camcorder User Manual


 
3 - 18 C156-E097-01EN
Table 3.4 Recommended components for connection
Category Name Model Manufacturer Symbol in Figure
3.19
SCSI cable Cable socket
(closed-end type)
FCN-707B050-AU/B Fujitsu Ltd. S01
Cable socket
(through-end type)
FCN-707B050-AU/O Fujitsu Ltd.
Signal cable UL20184-
LT25PX28AWG
Hitachi Cable, Ltd.
455-248-50 SPECTRA-STRIP
Power supply cable Housing for cable
socket
1-480424-0 AMP S2
Contact 170121-4 AMP
Cable AWG18
External operator panel Housing for cable
socket
LPC-16F02 Honda-Tsushin SH2
Receptacle LPC-F104N Honda-Tsushin
Cable AWG28
(1) SCSI cable
All SCSI devices on one bus are daisy-chained with an SCSI cable. A terminating resistor must
be mounted in the SCSI device at each end of the SCSI cable.
A terminating resistor is mounted on the drive when the drive is shipped. A terminating resistor
must be disconnected when the drive is not connected to an end of the SCSI cable. Select a
method of power supply to the terminating resistor circuit according to the setting pins on the
drive. See Section 4.3 for details.
Up to eight SCSI devices can be connected to the SCSI bus. SCSI devices include the host
adapter, the optical disk drive, and other SCSI equipment.
The connector (socket) for the SCSI cable must be an unshielded 50-contact socket with two
rows of 25 contacts on 2.54 mm (0.1 inch) centers. The connector should also be polarized or
keyed to prevent misinsertion. (See Figure 3.17.)