JVC GY-DV550 Camcorder User Manual


 
7. SHOOTING OPERATION
56
1.
In the record-pause or stop mode, approximately 7 seconds of
the last recorded portion can be played back.
The recorded contents can be checked in the viewfinder or
on a monitor connected to the MONITOR OUT or Y/C OUT
connectors.
In the viewfinder or on the monitor connected to the
MONITOR OUT or Y/C OUT connectors, the video image
from the VCR section is output.
1.
In the record-pause or stop mode, press the RET button on
the camera lens section.
The tape is slightly rewound and played back for
approximately 7 seconds.
After playback is finished, the tape returns to the position
at which the RET button is pressed and the record-pause
mode resumes.
When the RET button is kept pressed, the tape is rewound
and played back for approximately 18 seconds at maximum.
While the RET button is pressed, the record-mode is not
entered even if the VTR trigger button is pressed.
7-4
Checking Recorded Contents in Record-Pause Mode
(Recording Check Function)
*During recording check, the following indications will
appear if the error rate increases due to head clogging,
etc.
RF appears on the display panel.
HEAD CLOG appears on the counter display.
VTR WARNING (HEAD)
appears in the viewfinder.
* Recording check cannot be performed for an external
VCR.
RET button
7. SHOOTING OPERATION
55
When the GY-DV550 has remained in record-pause (standby)
mode for about 30 minutes, the unit enters the save mode, in
which the drum rotation is stopped automatically and the tape
tension is released. (Tape protect mode)
To start recording from the tape protect mode, press the VTR
trigger button; the drum starts to rotate and recording starts
in about 3 seconds.
To return to the record-pause mode from the tape protect
mode, press the VTR trigger button TWICE; the drum starts
to rotate.
7-2 VCR Save Mode
7-3 If Unit is Left in Record-Pause (Standby) Mode
The time until the unit enters the tape protect mode after
it is placed in record-pause mode can be set to 3 minutes
or 30 minutes with the VCR Setup Menu item No. 307
LONG PAUSE TIME.
When used in a cold environment, the setting will be 3
minutes regardless of the setting on the VCR Setup
Menu.
See page 75.
When the VCR Setup Menu item No. 396 SSF MODE
is set to the CUE MODE or MARK mode, the VCR
save mode is not entered.
External VCR will not enter the SAVE mode.
CAUTION:
SHUTTER STATUS
MENU
FILTER
3200k
1
5600k+1/8ND
2
5600k+1/64ND
3
ALARM
MONITOR
OPERATE
NG
G
A
IN
O
U
T
PU
T
W
H
T
.B
A
L
V
T
R
ON OFF
AUTO IRIS
LOLUX
BACK L
NORMAL
SPOT L
STRETCH
NORMAL
COMPRESS
LIGHT
ON
OFF
COUNTER
AUDIO SELECT
MANUAL
AUTO
CH-1 CH-2 CH-1 CH-2
REAR
FRONT
RM
AUDIO INPUT
MODE
CTL
TC
UB
CH-1
MIX
CH-2
RESET
OPERATE/WARNING
MONITOR
SELECT
CH-1
AUDIO
LEVEL
CH-2
VTR
ON
OFF
INCOM
MIC
INCOM
MIC
LEVEL
POWER
OFFRM
DC IN
/BATT.
CALL
CARBON
DYNAMIC
FULL AUTOBLACK
ACCU -FOCUS
G
F
I
F5.6
STBY 4V21.<60
B
SD
CH1-----+--
CH2-----+--
M: 909
OPERATE
NG
GAIN
OUTPUT
WHT.BAL
VTR
ON OFF
STBY
or
SAVE
VTR
switch
(Status 1 mode)
VCR operation
status display
Viewfinder
When a recordable videocassette is loaded, the GY-DV550
enters the record-pause mode. However, the record-pause
operation condition differs depending on the setting of the VTR
switch.
VTR switch setting
STBY : The GY-DV550 enters the record-pause mode, and
the drum is rotating at this time. (Standby mode)
The "STBY" indicator appears in the VCR operation
status display in the viewfinder (in Status 1 mode).
In this condition, recording starts immediately when
the VTR trigger button is pressed.
SAVE : The GY-DV550 enters the record-pause mode but
the drum is not rotating. (Save mode).
The tape is protected.
The "SAVE" indicator appears in the viewfinder (in
Status 1 mode).
The OPERATE indicator lights orange.
Recording from the Save mode
In the save mode, pressing the VTR trigger button will start
recording.
However, in this case, it takes several seconds before the
GY-DV550 starts recording.
Pressing the VTR trigger button again interrupts the recording
and the GY-DV550 enters the save mode again.