Chapter 6 LEDs and DIP Switches
NI 17xx Smart Camera User Manual 6-4 ni.com
IMG ACQ LED
The IMG ACQ LED briefly lights green when an image is captured and
ready for analysis. Fast frame rates can give this LED the appearance of
being continuously lit.
If the IMG ACQ LED and the FAIL LED both flash red, it indicates that
the NI Smart Camera has shut down because the maximum internal
temperature was exceeded. Refer to the Thermal Considerations section of
Chapter 8, Thermal Considerations and Mounting, for information about
measuring the temperature of the smart camera. Refer to Appendix A,
Specifications, for complete specifications.
PASS LED
The PASS LED is a green LED that is user-configurable through the
IMAQ property node in LabVIEW or the Read/Write I/O step in Vision
Builder AI.
FAIL LED
The FAIL LED is a red LED that is user-configurable through the
IMAQ property node in LabVIEW or the Read/Write I/O step in Vision
Builder AI.
If the IMG ACQ LED and the FAIL LED both flash red, it indicates that
the NI Smart Camera has shut down because the maximum internal
temperature was exceeded. Refer to the Thermal Considerations section of
Chapter 8, Thermal Considerations and Mounting, for information about
measuring the temperature of the smart camera. Refer to Appendix A,
Specifications, for complete temperature specifications.
Configuring DIP Switches
This section describes the SAFE MODE, IP RESET, NO APP, and
CONSOLE DIP switches on the NI Smart Camera. To turn on a DIP
switch, lift the DIP switch cover and move the switch to the ON position.