Appendix B Troubleshooting
NI 17xx Smart Camera User Manual B-6 ni.com
Make sure that you have enabled the corresponding external lighting
strobe in MAX or Vision Builder AI. Complete one of the following
procedures to enable the correct lighting strobe.
MAX
1. Launch MAX.
2. In the Configuration tree, expand Devices and Interfaces.
3. Expand NI-IMAQ Devices.
4. Expand the smart camera you are using.
5. Select the channel you are using.
6. Select the Lighting tab.
7. Select the appropriate strobe from the External Strobe Generation
control.
Vision Builder AI
1. Launch Vision Builder AI.
2. In the Acquire Image (Smart Camera) step, select the Lighting tab.
3. Select the appropriate strobe from the External Strobe Generation
control.
Triggering Problems
No Trigger is Received
If you are not receiving a trigger, verify the following:
The trigger is wired to the TrigIn+/IsoIn(0)+ and TrigIn–/IsoIn(0)–
signals.
If TrigIn/IsoIn(0) and IsoIn(1) are both being used, that the devices
they are connected to are either both sinking (NPN) or both sourcing
(PNP).
The trigger is connected correctly based on the type of sensor it
is—sourcing or sinking. Refer to the Isolated Inputs section of
Chapter 2, Power and I/O, for information about connecting isolated
inputs.
The sensor power supply is of appropriate voltage for interfacing to
NI Smart Camera isolated inputs. Refer to the Isolated Inputs section
of Chapter 2, Power and I/O, for information about isolated inputs.
Refer to Appendix A, Specifications, for complete specifications.