158
Maintenance and Inspections: Maintenance
LENS
Panasonic part number K1AY112JA001
1 RET-SW On/off of the return video
RETURN ON: GND
RETURN OFF: OPEN
Maker part number HR10A-10R-12SC(71)
(Hirose Denki)
2REC-START/
STOP
Control for recording start/stop
3GND GND
4 IRIS-AUTO On/off of the forced iris servo
SERVO ON: +5 V±0.5 V
SERVO OFF: OPEN
5 IRIS-CONT Control output for the lens iris
F2.8: –6.2 V, F16: +3.4 V, CLOSE: +2.5 V
6 UNREG-12 V +12 V power supply for the lens (Max. 1.5 A)
7 IRIS-POSI Iris position signals
+3.4 V (F16) to +6.2 V (F2.8)
8 IRIS-G-MAX IRIS REMOTE/LOCAL (AUTO) signals
REMOTE: +5 V±0.5 V
LOCAL (AUTO): GND
9 EXT-POSI On/off of the built-in extender
EXTENDER ON: GND
EXTENDER OFF: OPEN
10 ZOOM-POSI Zoom position signals
11 FOCUS-POSI Focus position signal
12 SPARE Standby (not used)
GPS
Panasonic part number K1AY106J0001
1 GPS TXA Transmission data from the GPS unit to the camera
Maker part number HR10A-7R-6SC(73)
(Hirose Denki)
2 GPS RXA Transmission data from the camera to the GPS unit
3 GPS VBAT Backup power supply connector for the GPS unit
(DC +3.3 V)
4 REC START SW Control signals of recording start/stop
5 GPS VCC Power supply connector for the GPS unit (DC +3.3 V)
6GPS GND GND
START STOP START
+5 V
0 V
1
2
4
5
6
3
7
8
9
10
11
12
1
2
4
5
6
3
AJ-HPX3700G-VQT1V68_eng.book 158 ページ 2008年10月15日 水曜日 午後6時38分