24 VAC CONNECTOR
Single Camera Wiring
If PoE is not available:
1. Connect the 24 VAC wires to the supplied 2-pin connector (refer to Figure 15).
NOTE: Only use the 24 VAC wires if PoE is not available.
2. Attach the mating connector to the green connector on the side of the camera.
Figure 15. 24 VAC Connector
Multiple Camera Wiring
If you are operating the camera using 24 VAC and you are wiring more than one camera to the same transformer:
1. Connect one side of the transformer to pin 1 of the 2-position terminal block on all modules.
2. Connect the other side of the transformer to pin 2 of the terminal block on all modules.
NOTE: Failure to connect all modules identically might introduce video noise for some installations
ALARM AND RELAY CONNECTOR
1. Connect the alarm and relay wires to the supplied 4-pin connector (refer to Figure 16).
2. Attach the mating connector to the green connector on the side of the camera.
.
Figure 16. Alarm and Relay Connector
24V~
RELAY
R1
ALARM
A1