24 C311M-O (11/07)
ACK ACT (ACKNOWLEDGE ACTION)
If an enivornmental condition inside of the IOC goes outside of the factory set limits (such as Low Pressure) then select ACK Alert to activate the
alert label behavior. Program ACK Act to establish alert label behavior after alert acknowledgement. The following acknowledge actions are
available:
• Always on: The alert label is displayed until alert conditions are clear.
• Off 8 hrs: The alert label is turned off for 8 hours. Label returns after 8 hours if the alert condition persists.
• Off 24 hrs: The alert label is turned off for 24 hours. Label returns after 24 hours if the alert condition persists.
• Off 48 hrs: The alert label is turned off for 48 hours. Label returns after 48 hours if the alert condition persists.
To set the acknowledge action:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Alert.
3. Press the Iris Open button to enter the Alert menu.
4. Position the cursor (>) beside ACK Act.
5. Press the Iris Open button. The cursor moves to the right.
6. Move the joystick up or down to make a selection.
7. Press one of the following buttons on your keyboard:
• Iris Open: Press the Iris Open button to select your choice.
• Iris Close: Press the Iris Close button if you do not want to change the setting.
MAIN MENU
<Camera>
<Line Sync>
<Power Up Mode>
<Wiper>
<Limit Stops>
<Text Display>
<Alert>
<Other>
ACK Alert
Exit
Repeat Constant
Alert Disp Row
Disp Pos Right
ACK Act Always On
<Currrent Reading>
Alert Reset
Exit
Alert Menu