52 C311M-O (11/07)
RESET CAMERA
Resetting the camera returns the settings to their defaults.
Turning off power does not reset the camera. Camera settings are retained in memory. When the power is turned back on, the settings will be the
same as they were when the power was turned off.
To reset the camera:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Reset Camera.
5. Press the Iris Open button to reset the camera.
35X Models 24X Models 22X Models 16X Models
Default Setting
Backlight Comp Off Off Off Off
Zoom Limit No default No default No default No default
Gain/AGC
Gain Limit 25 25 25 27
Auto Iris
Mode
Level
Peak
NTSC PAL
Auto Auto
116
16
NTSC PAL
Auto Auto
106 96
16 16
Auto
66
16
NTSC PAL
Auto Auto
66 57
816
Low Light Limit 222N/A
Shutter Speed Auto Auto Auto Auto
Auto Focus Mode Auto Auto Auto Auto
IR Filter
IR Filter Mode
Auto IR Level
Off
Dusk
Auto
Dusk
N/A
N/A
N/A
N/A
Sharpness
Auto Sharpness
Sharpness
On
No defaults
On
No default
On
No default
On
No default
White Balance
Auto White Bal
R Gain
B Gain
On
No default
No default
On
No default
No default
On
No default
No default
On
No default
No default
Backlight comp Off
Zoom limit x- -
Reset camera
<Gain/AGC>
<Auto iris>
Next
Exit
Camera Menu
MAIN MENU
<Camera>
<Line Sync>
<Power Up Mode>
<Wiper>
<Limit Stops>
<Text Display>
<Alert>
<Other>
ACK Alert
Exit