CURRENT READING MENU
The Current Reading menu displays the existing status of temperature, pressure, and dewpoint inside the integrated optics cartridge. An asterisk
displayed to the left of a menu item denotes that an alert condition exists.
Due to the heat emitted from the electronics of the camera, normal temperature operating range is approximately 95°F.
PAN/TILT FUNCTIONS
If the proportional pan mode is enabled (refer to Proportional Pan on page 51 in the Programming section), the pan/tilt speeds will depend on the
amount of zoom. At telephoto zoom settings, the pan/tilt speeds will be slower for a given amount of joystick deflection than at wide zoom
settings. This keeps the image from moving too fast on the monitor when there is a large amount of zoom. This slowing does not happen when
going to a preset, but does occur in Turbo mode when high zoom is selected. The minimum pan and tilt speeds are 0.1 degree per second at full
zoom.
SCAN SPEED
Scan speed is adjustable from 1 to 40 degrees per second through the programming menu.
PRESET FUNCTIONS
The Esprit system is capable of going to 64 preset locations, each with a 20-character label. The presets are numbered 1 to 32 and 35 to 66. Refer
to the documentation for your control system for programming presets.
If you command the pan/tilt to go to an undefined preset, erratic operation may result.
Presets 33 and 34 are fixed commands, meaning that you cannot program them. Preset 33 is the “flip” command, which will pan the system
180 degrees. Preset 34 is the “pan zero” command, which will pan the system to the factory-determined zero reference point.
RANDOM, FRAME, AND AUTO SCANNING
Select preset 97 (30) to start random scanning. Select preset 98 (31) to activate frame scanning (three seconds of scanning followed by a three-
second pause). Select preset 99 (32) to start auto (continuous) scanning. Scan limit stops are controlled by software. Refer to Limit Stops on
page 42 to program the scan limit stops.
When the pan/tilt reaches a scan limit stop, it reverses direction. Select preset 96 (29) to stop a scan. Any pan and tilt or lens command will also
stop a scan.
Controller
Type
Pan
(Capability: 360° Continuous Pan Rotation)
†
Tilt
(Viewing Range: +33° to -83°)
‡
Fixed speed Speed determined by controller Speed determined by controller
Variable speed*
Turbo Mode*
Preset Mode*
0.1 to 40° per second, depending on joystick and zoom
positions
100° per second
100° per second
0.1 to 20° per second, depending on joystick and zoom
positions
Does not affect the tilt speed
30° per second
*50 mph wind speed profile.
†
If manual limit stops are set, Pan Limit appears on your monitor when a limit stop is reached (except when you are programming or running
a pattern). This does not apply to scan limit stops.
‡
When the system reaches the upper limit, Tilt Limit appears on your monitor (except when you are programming or running a pattern).
Temperature 37 C
98 F
Dewpoint 08 C
46 F
Pressure 10.30 psig
0.71 bar
Refresh
Exit
IOC Internal Reading