e-21e-20
1-4) CAMERA Composition and Connecting Method to
SYSTEM
After positioning monitor and installing three cameras to a desired location, please connect CAMERA
to SYSTEM through CAMERA CABLE (MCB-60 or MCB-100) as shown in the below figure. Please
check whether or not it is properly connected.
Connection status checking method :
• Turn on the monitor after connecting cameras, and check if camera image is displayed.
The initial screen mode of monitor is quad mode.
• If the camera is not connected to the monitor, information on the video loss will be
displayed on the black screen.
•
Loosen the handle by turning it in a counterclockwise direction and then adjust the camera
position . Tighten the handle, turning it clockwise, and lock the camera in position.
•
Connect the camera cable to the camera.
(3) Specifications
Use : Indoor
Installation : Wall or Ceiling
Dimensions : 57 (W) X 47.2(H) X 100.5(L)
Weight : 150g
Operating Temperature : -10
°C
~ 50
°C
(4) Accessories
SCREW (M4 X L15) : 3 pcs
Handle
00403A SSC-17TQ_ENG 10/9/03 11:30 AM Page e-20