FRAME mode
When an alarm signal for a specific camera is input,
the picture of the camera in alarm status is recorded
only for one frame immediately after the alarm input.
The recording mode for alarm recording is fixed to
HYPER (the highest image quality mode exclusive for
this FRAME mode), and Cancel condition to 1 frame.
In this case, the maximum recording cycle is about 4
frames per second.
Note
Any alarm input in FRAME mode is not registered to
the alarm list.
Cancel condition of Alarm recording
For alarm recording other than Frame mode, you can
select the condition to cancel recording from among
the following.
•30SEC, 1MIN, 2MIN, 3MIN, 5MIN, 7MIN, 10MIN:
The specified time has elapsed.
•ALM OFF: The alarm input stops.
•TAPE END: Recording reaches the end of the tape.
To set the Alarm mode
The setting is made on a special display on the monitor
screen.
Once you set the mode, it is not necessary to
repeatedly set it if it is not to be changed.
See Chapter 4 “Menu Operations” for additional information.
1 Enter Menu mode by pressing the MENU key.
2 Highlight REC FUNCTION MENU of the Top
menu (page 4-5) by pressing the V or v key, then
press the b key.
The Recording Function menu is displayed.
SETUP MENU
REC FUNCTION MENU
NORMAL REC : MODE 1
TIMER REC
M ALARM REC
REPEAT REC : OFF
CONTINUOUS REC
1)
: OFF
SETTING OF REC MODE
3 Highlight ALARM REC by pressing the V or v
key, then press the b key.
The menu shifts to the selection layer of alarm
recording.
SETUP MENU
REC FUNCTION MENU
ALARM REC
M ALARM REC : OFF m
ALARM SET
4 Highlight ALARM SET by pressing the V or v
key, then press the b key.
The alarm set display appears on the monitor
screen.
ALARM SET
ALARM REC : NORMAL
REC MODE : REC 5
CANCEL : 30 SEC
SHIFT: µ CHANGE : Mm
DATA SET: SET MENU : MENU
5 Select the desired Alarm REC mode by pressing
the V or v key, then press the b key.
1 frame
No recordingNo recording
Alarm input
Alarm recording (HYPER mode)
(Continued)
1) HSR-1/1P only