D-2
P 300STD/FZY/PRO Scanner Product Reference Guide
2-D Decode Depth of Field See P 300FZY Decode Zone on page D-4
Print Contrast Minimum MRD 25% absolute dark/light differential, measured at 650
nm.
*For direct host power connection, make sure the host terminal supplies sufficient power for the
specified operation. Symbol is not responsible for damage to host equipment or system mis-
operation due to an insufficient power condition.
Ambient Light Immunity
Artificial Lighting
Sunlight
450 ft. candles 4844 lux
9000 ft. candles 96876 lux
(@8 in. (20 cm) on low density bar codes)
Operating Temperature -30° to 50°C (STD/FZY -20° to 50°C (PRO)
Storage Temperature -40° to 140°F -40° to 60°C
Humidity 5% to95% (non-condensing)
Durability 6-ft. drop to concrete 1.8 m
Dimensions
Height
Length
Width
7.0 in. 17.80 cm
9.2in. 13.50 cm
3.5 in. 9.80 cm
Laser Classifications CDRH Class II
IEC 825 Class 2
Laser Power 0.81 mW ±0.07mW
Table D-1. Technical Specifications (Continued)
Item Description