Laser On Time
This parameter sets the maximum time decode processing continues during a scan attempt.
It is programmable in 0.1 second increments from 0.5 to 9.9 seconds.
To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes beginning
on page 2-120 that correspond to the desired time on. Single digit numbers must have a
leading zero. For example, to set a Time On of .5 seconds, scan the bar code below, then scan
the “0” and “5” bar codes. If you make an error, or wish to change your selection, scan
CANCEL
on page 2-122.
Laser On Time