Symbol Technologies P 300STD/FZY/PRO Scanner Photo Scanner User Manual


 
1-16
P 300STD/FZY/PRO Scanner Product Reference Guide
Macro PDF
Table 1-2 provides beeper definitions for Macro PDF mode.
Beeper Sequence Indication
Code 39 Buffering
High/low tone New Code 39 data was entered into the buffer.
3 Beeps - long high tone Code 39 buffer is full.
Low/high/low tone The buffer was erased, or there was an attempt to
transmit an empty buffer. When the Code 39 buffer was
empty, the scanner read a command to clear or to
transmit a Code 39 buffer.
4 Beeps - long low tone Error in data transmission.
Low/high tone A successful transmission of buffered data.
Table 1-2. Macro PDF Beeper Indications
Beeper Sequence Indication
Error
1 Low Long Hi-level decode error caused by incorrect
symbol.
2 Low Long File ID error. A bar code not in the current
MPDF sequence was scanned.
3 Low Long Out of memory. There is not enough buffer
space to store the current MPDF symbol.
4 Low Long Bad symbology. You scanned a 1-D or 2-D
bar code in an MPDF sequence, a duplicate
MPDF label, an incorrect sequence, or are
trying to transmit an empty or illegal
MPDF field.
5 Low Long Flushing buffer.
Fast Warble Successful parameter scanned.
Decode Beep Sequence
Table 1-1. Beeper Indications (Continued)