2-54
P 300STD/FZY/PRO Scanner Product Reference Guide
Code 39 Check Digit Verification
When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies
with specified algorithms.
Only those Code 39 symbols which include a modulo 43 check digit are decoded when this
parameter is enabled.
Enable Code 39 Check Digit
Disable Code 39 Check Digit