4.2.4 Basic Alignment
of the Video Output
If the video image can not be centered on the video monitor
vertically, as described in chapter 5.3, it is possible to align
the CCD optic module mount.
For this, the following tools are needed:
Phillips screw driver size 0
Phillips screw driver size 1
1.5 mm allen key
Disconnect camera from all power supplies!
Do not use force! Ensure clean contacts!
Support the viewfinder system!
Do not touch optic surfaces!
Take the viewfinder system off the camera by lifting
the release button §.
Open the 7 mounting screws §.
Open the 3 mounting screws §.
The viewfinder top is connected with two cables
to the rest of the units.
Do not use force in separating the units!
release button
7 monting screws
3 monting screws