Axis Communications M1034-W Security Camera User Manual


 
AXIS M1034-W Network Camera
PTZ (Pan Tilt Zoom)
2. Enter a descriptive name.
3. Specify the pause length between runs.
4. Select an available prese t position and click Apply.
5. Specify the View Time in seconds or minutes.
6. Specify the View Order or select the Random view order option.
7. Click Save.
To mo dify or remove guard tours, go to PTZ>GuardTour, select the guard tour in the Guard Tour List and click Modify/Remove.
For more i nformation see the online help
.
Advanced
Controls
Panel Shortcut Command Buttons can be congured to provide direct access to commands issued via the VA PIX® Application
Programming Interface. The buttons will be displayed in the PTZ control panel, which is a vailable in the Live View page through
the Ctrl panel button, see
page 13
.
Control Queue
The administrator can set up a queue for PTZ controllers from PTZ > Control Queue. O nce set up, the PTZ Control Queue buttons
appear in the Live View page offering one viewer exclusive control for a limited period of time. Other users will be placed in queue.
A user who belongs t o a group (see
Users, on page 38
) with a higher PTZ priority can go before other users in the queue and
take contr ol of the product. The order of priority is as follows:
1. Administrator — An administrator takes o ver PTZ control regardless of who is rst in queue. The administrator w ill be
removed from the queue 60 seconds after the last PTZ control
command.
2. Event — The Axis product can be conguredtogotoapr
eset position when triggered by an alarm (see
Events, on page 32
).
The event will imme diate ly be placed rst in the queue except when an administrator is in control.
3. Operator Same as administrator but with lower priority
4. Guard Tour — A guard tour (see
page 27
) has PTZ control for an indenite period of time. It may be overridden by an
operator, event or administrator. The guard tour will resume when higher priority groups leave the q ueue.
5. Viewer Multiple viewers must wait for their turn. The viewer has 60 seconds PTZ co ntrol before control is passed
on to the nex
t viewer in queue.
Note
The administrator can enable and disable PTZ controls for selecte d users.
•Toid
entify different users in the viewer group, cookies must be enabled on the client.
28