Bosch Appliances VG5 700 series Security Camera User Manual


 
AutoDome 700 Series IP PTZ Camera VG5 Audio Connections | en 17
Bosch Security Systems, Inc. User Manual F.01U.215.777 | 1.0 | 2011.07
3.1.4 Enabling Audio Transmission
To transmit audio via the IP connection, do the following:
1. Open the AutoDome 700 Series Livepage, then click the Settings tab.
2. Click Service Settings from the left pane, then click Livepage Configuration. The
AutoDome 700 Series displays the Livepage Configuration screen (see Figure 3.2).
3. Click the Transmit Audio radio button to enable for audio.
Figure 3.2 Livepage Configuration
3.1.5 Configuring Gain (optional)
Input gain control is supported over a range of -34dB to +12dB. The current video image is
shown in the small window next to the slide controls to help verify the audio source and
improve the Peak levels. Set the gain of the audio signals to suit your specific requirements.
Changes are effective immediately. The current level is displayed next to the slide control to
help do this. Make sure that the display does not go beyond the green zone during
modulation.
Figure 3.3 Setting Audio