Bosch Appliances VG5 700 series Security Camera User Manual


 
AutoDome 700 Series IP PTZ Camera Configuring the AutoDome 700 Series | en 51
Bosch Security Systems, Inc. User Manual F.01U.215.777 | 1.0 | 2011.07
4.42 Alarm Task Editor
As an alternative to the alarm settings on the various alarm pages, you can enter your desired
alarm functions in script form here. This will overwrite all settings and entries on the other
alarm pages.
1. Click the Examples link under the Alarm Task Editor field to see some script examples. A
new window will open.
2. Enter new scripts in the Alarm Task Editor field or change existing scripts in line with
your requirements.
3. When you are finished, click the Set button to transmit the scripts to the unit. If the
transfer was successful, the message Script successfully parsed is displayed over the
text field. If it was not successful, an error message will be displayed with further
information.
4.43 Alarm Rules
The AutoDome 700 Series features an alarm rule engine. In its simplest form, an alarm rule
can define which input(s) activate which output(s). Basically, an alarm rule allows you to
customize an AutoDome 700 Series to automatically respond to different alarm inputs.
To configure an alarm rule specify one input from either a physical connection, a motion
detection trigger, or from a connection to the camera’s Livepage. The physical input
connection can be activated by dry contact devices such as pressure pads, door contacts and
similar devices
Next, specify up to two (2) rule outputs, or the camera’s response to the input. Outputs
include a physical alarm relay, an AUX command, or a preposition scene.
1. Click the Enabled check box to activate the alarm.
2. Choose one of the following alarm inputs:
Local Input 1: a physical alarm connection.
Local Input 2: a physical alarm connection.
IVA/MOTION+: an alarm when IVA or motion detection is activated.
Connection: an alarm when an attempt is made to access the camera’s IP address.
3. Choose one of the following output commands for both Output 1 and Output 2 settings:
None: no defined command.
Alarm Relay: defines a physical connection from the open collector alarm output.
Aux On: defines a standard or custom keyboard ON command.
Refer to Section 6 User Command Table, page 64, for a list of valid commands.
Note: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the
remaining commands is scheduled for a future release.
Aux Off: defines a standard or custom keyboard OFF command.
Refer to Section 6 User Command Table, page 64, for a list of valid commands.
Note: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the
remaining commands is scheduled for a future release.
Shot: defines a preset scene from shot 1-99.
4. Click Set to save and to activate the alarm rules.
CAUTION!
Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
procedure cannot be reversed.
In order to edit this page, you must have programming knowledge and be familiar with the
information in the Alarm Task Script Language document.