3-3
3.1 Cleaning Materials and Areas Requiring Cleaning
3
DAILY CARE
■ Locations requiring Cleaning and Cleaning
Frequency
The following shows the standard cleaning frequency for each area requiring
cleaning.
Part to clean Standard Cleaning Frequency
Pad Clean every 100,000sheets
Pick roller Clean every 100,000sheets
Brake roller
Separation roller
Feed roller
Pinch roller
Transport path Clean every 200,000sheets
Discharge brush Clean every 100,000sheets
Removable sheet guide Clean every 200,000sheets
Glass sheet guide
Document width detection sensor Clean every 200,000sheets
Ultra sonic sensor
SF0
SF1
SF1.5
SF2
Front-side Lamp Clean every 100,000sheets
Back-side lamp
ATTENTION
Please clean rollers using the cleaning sheet every 50,000 sheets.