58
3.5 Cleaning the Discharge Brush
2. Pull the ADF release lever toward you and lift up the ADF sheet guide.
3. Slide the Pick roller unit leftward a little and disengage the right ring form the shaft.
4. Pressing down the upper part of the guide plate with your fingers at two positions
and pull the plate toward you to remove it.
#&(WRRGTUJGGVIWKFG
#&(TGNGCUGNGXGT
Pick roller unit
Ring(hidden)
Shaft(hidden)