Grundig GV 460 VPT / NIC Camcorder User Manual


 
GV44…, GV45…, GV46… Abgleichvorschriften / Adjustment Procedures
GRUNDIG Service-Technik 3 - 5
GB
Adjustment Procedures
1. Power Supply (PS)
Test Equipment: Digital Voltmeter.
Service work after replacing the Power Supply:
Adjustment Preparation Adjustment Procedure
+12V
D
Adjust voltage to 12V ±0.1V with R3090.Digital voltmeter:.................................................. MP
1
Playback.
2. Family Board
Service work after replacing the Family Board:
– 2.1 Sequence Control ..................................... Adjustment no. 1, 2
2.4 Video ........................................................ Adjustment no. 3, 5
– 2.6 FM Sound ................................................. Adjustment no. 2, 3
– 2.7 Standard Sound .......................................Adjustment no. 1…4
2.1 Family Board – Sequence Control /Deck Electronic (DE)
Test Equipment: Oscilloscope, 10:1 Test Probe, Frequency Counter.
Service work after changing:
Family Board: Adjustment no. 1, 2
the IC7058: Adjustment no. 1
2.3 Frontend – Adjustment no. 6, 7
the IC7060: Adjustment no. 1…3
2.4 Video – Adjustment no. 5
Adjustment Preparation Adjustment Procedure
Press the buttons
>
and V simultaneously on the recorder and connect the mains plug.
In doing so, the following channels are set on the first 5 programme positions for frontend adjustment (vision
demodulator circuit):
Programme 1 – channel 12; programme 2 – channel 21; programme 3 – channel 68
programme 4 – channel 8; programme 5 – channel 60
Warning: This function erases all data entered by the customer (stations selected, …)!
– Load a test cassette. The video recorder then switches automatically to play mode.
– Call up the service function:
Press the Z button on the remote control handset ("
CODE – – – –
" is indicated in the display).
Enter the code number 4 9 3 4 and press the O button ("
SERV
" is indicated in the display).
Press the 3 button.
During the automatic adjustment of the headwheel position indicator the display shows "
DRUM 00
00
A3
".
On successful adjustment the video recorder ejects the test cassette.
– To cancel the service function: Mains reset or press the "Standby" button.
Connect IC7060-(7) to +5V
D
via a 10k resistor.
Frequency counter to IC7060-(7).
Standby.
1. Initializing the
RAM (IC7060) and
EEPROM (IC7058)
2. Headwheel
Position Indicator
3. Clock, C2060
Set clock period to 1s ±4µs via C2060. Remove the 10k
resistor.