JVC GY-HD110 Camcorder User Manual


 
42
PREPARATIONS FOR OPERATION
Synchronizing with the Time Code of the IEEE1394 (DV)-Connected Master Unit
You can synchronize the time code when performing multi-camera recording. The internal time code generator will be synchro-
nized with the timed code in the signal input from the IEEE 1394 terminal. After synchronization (slave lock), the internal time
code generator continues to run even if the IEEE1394 cable is disconnected.
* You can use the GY-HD110U or GY-HD111E as a slave unit. You cannot use the GY-DV110E as a slave unit.
Connections
Connect the master unit and the slave unit with an IEEE1394 cable.
Settings and Operations
Master unit (GY-HD100U/GY-HD100E/GY-HD101E/GY-HD110U/GY-HD110E/GY-HD111E)
1. Set the IEEE1394 switch on the left side to [DV].
2. Set to Camera mode.
3. Set the recording format to DV-60I or DV50I.
4. Set the TC GENE. switch to [FREE].
Slave unit (GY-HD110U/GY-HD111E)
1. Set the IEEE1394 switch on the left side to [DV].
2. Set to VTR mode.
3. Check that the camera image from the master unit is input.
4. Set the TC GENE. switch to [FREE] and the TC DISPLAY switch to [TC].
5. Set to STOP mode or EJECT mode.
6. Press the STOP button for 1 second.
The DV input time code data from the IEEE1394 terminal is displayed in the status
display. (When status is in magnified size, images and characters are displayed.)
7. Press the USER1 button to begin slave lock.
(To skip slave lock, press the USER3 button and clear the status display.)
8. Check that the time code that is synchronized with the master unit is running.
9. Disconnect the IEEE1394 cable.
MEMO
Slave lock cannot be performed in the following instances.
Slave unit is in CAMERA mode
Slave unit is in VTR mode and there is no DV signal
The TC GENE. switch on the slave unit is not set to FREE
The slave unit is GY-HD110E
HDV format
If slave lock is performed in DV format and is then switched to HDV format, frame digit may deviate.
If power is turned off, slave lock is disabled. Perform slave lock operation again.
Slave lock cannot be performed for UB (User’s bit).
If the frame rate for the master unit and slave unit is not synchronized, it will not run properly. Synchronize frame rate before
using.
If DROP/NON DROP is not synchronized, it will not run properly. Synchronize DROP/NON DROP before using.
MACRO
MACRO
Master unit Slave unit
IEEE1394 cable
IEEE1394 terminal IEEE1394 terminalSlide the IEEE1394
switch to the [DV] side.
Slide the IEEE1394
switch to the [DV] side.
DTCG
TC SLAVE LOCK ?
EXECUTE USER1
00 : 00 : 00 : 00
CANCEL
USER3
St
a
t
us
di
sp
l
ay