90
OTHERS
Warnings and Responses (Cont’d)
• Warning Indications for VTR Abnormalities
Should malfunctions occur during VTR operation, the unit
self-diagnoses the cause and shows the diagnose together
with an error code on the LCD monitor or in the viewfinder.
Error code
Warning
Error Code Error Details GY-HD110 Operation Remedy
0201
CONDENSATION ON DRUM
Indicates dew formation (condensa-
tion).
Operation stops. All opera-
tions are rejected.
Leave the unit with the power ON, until
the indication disappears.
3200
LOADING FAILURE
Tape cannot be loaded. Switch the power OFF and then switch
it back ON. However, the tape may be
damaged depending on the circum-
stances. Please consult the person in
charge of professional video equip-
ment at your nearest JVC-authorized
service agent.
3300
UNLOADING FAILURE
Tape cannot be unloaded.
4100
CASSETTE EJECT FAILURE
Irregularity with eject operation.
5605 - 5609
DEFECTIVE TAPE
Tape is cut. Operation stops. Press the EJECT button to take out the
cassette.
5702
TAPE END DET. ERROR
Tape end sensor error. Operation stops. All opera-
tions are rejected.
Switch the power OFF and then switch
it back ON. However, the tape may be
damaged depending on the circum-
stances. Please consult the person in
charge of professional video equip-
ment at your nearest JVC-authorized
service agent.
5802
TAPE BEGIN DET. ERROR
Tape beginning sensor error.
7001
DRUM MOTOR FAILURE
Drum rotation error.
7101
CAP MOTOR FAILURE
Capstan rotation error.
7202 - 7203
SUPPLY REEL FAILURE
Supply reel rotation error.
7302 - 7303
TAKE UP REEL FAILURE
Take up reel rotation error.
7305
TAKE UP REEL FAILURE
Take up reel rotation error when un-
loading.
8000
EMERGENCY TAPE!
Tape problem detected.
TURN POWER OFF.
TURN BACK ON LATER.
System error when power is turned on. HDV/DV LED, VTR indicator
and TALLY lamp flash. Only
POWER switch operation is
accepted.
Turn off the power and let the unit sit