JVC GY-HD110 Camcorder User Manual


 
78
MENU SCREENS
HEADER REC Menu Screen
The HEADER REC menu screen is used for settings related to the HEADER REC function. (X See page 52.)
Item Function/Setting (bold characters indicate initial settings)
START KEY Sets whether the HEADER REC operation should be executed when the REC/VTR trigger button is pressed while
the STOP button is pressed.
DISABLE : HEADER REC operation is not executed.
STOP+REC : HEADER REC operation is executed.
TC DATA Sets the time code value for the point when the Record-Standby mode is engaged following completion of HEADER
REC.
EXECUTE : Confirms the set time code.
ZERO PRESET : Resets all time codes to “0”.
CANCEL : Clears the set time code.
The frame mode is set depending on the setting in the DROP/NON DROP item on the TC/UB/CLOCK menu screen.
* The time code value at the point when the Record-Standby mode is engaged may differ some frames from the val-
ue set for this item.
UB DATA Sets the user’s bits of the HEADER REC section.
EXECUTE : Confirms the set user’s bits.
ZERO PRESET : Resets all user’s bits data to “0”.
CANCEL : Clears the set user’s bits.
MEMO
The user’s bits for the normal recording section are set on the TC/UB/CLOCK menu screen.
When the “UB REC” item is set to “OFF”, “--------” is displayed and this cannot be selected.
BARS TIME Sets the duration (seconds) in which the color bar signal and test tone (1 kHz) is recorded during HEADER REC. (1-
sec steps)
[Settings: 0SEC - 30SEC - 99SEC]
BLACK TIME Sets the duration (seconds) in which the black signal is recorded during HEADER REC. (1-sec steps)
[Settings: 0SEC - 30SEC - 99SEC]
PAGE BACK The TC/UB/CLOCK menu screen returns when the SHUTTER dial is pressed.