Maxis P1355 Camcorder User Manual


 
AXIS P1355 Network Camera
Technical Specifications
Connectors
I/O Connector
4–pin terminal block
For an example diagram, see Connection Diagrams on page 72.
Function Pin Notes
Specications
0 V DC (-)
1
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3.3 V DC
Max load = 50 mA
Digital Input
3
Connect to pin 1 to activate, or leave oating (unconnected)
to deactivate.
0 to max 40 V DC
Digital Output
4
Connected to pin 1 when activated, oating (unconnected)
when deactivated. If used with an inductive load, e.g. a relay,
a diode must be connected in parallel with the load, for
protection against voltage transients.
0 to max 40 V DC, open drain,
100 mA
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant
limited power source (LPS) with either a rated output power limited to 100 W or a rated output
current limited to 5 A.
Audio Connector
3.5 mm audio connectors
(stereo)
123
1 Tip 2 Ring
3 Sleeve
Audio Input
Microphone/Line in
Ground
Audio Output
Line out (mono)
Ground
71