Nikon LS-10E Photo Scanner User Manual


 
[8]
[b)
[g) [e)
Fig.
3.11
The internal-mount SCSI
bus
Le
bus
interne SCSI
Der Interne SCSI-Bus
[h)
[i)
[j]
Fig. 3.12 The special cable (not provided) required
to
connect
the
LS-10
In
the center
of
a SCSI
chain
50
Le cable special (non fourni) necessalre pour
connecter Ie LS-10
au
milieu d'une chaine
SCSI
Das zum
AnschluB
des LS-10
In
der MIHe der
SCSI-KeHe beniitigte Spezialkabel gehiirt
nlcht zum Lleferumfang
3-7 SeHing Up a SCSI Chain with
the LS-10
The LS-10
scanner
is equipped with one SCSI 50-pin
connector
. When the
scanner
is connected as the
only
other
device
on the chain,
or
as
the
last
device
on the
chain, then the connector of the 50-pin
cable
will
end
at
the
scanner
. This case is shown in Figure 3.
11
.
[a]
Computer
SCSI
controller
[b]
Computer
internal SCSI
termination
set
[c] Computer SCSI
connector
[d] SCSI
cable
[e] LS-10 SCSI
connector
[I] LS-10
scanner
[g] LS-10 SCSI
termination
switch
Typically, the
scanner
will be the
only
peripheral
on the
internal SCSI bus. If this is the case, the 50-pin
cable
provided
will
work
.
In
some
cases, as shown in
Figure
3.
11
. the LS-10
will
not be the
only
peripheral
on the internal SCSI bus.
When this occurs. the SCSI
cable
provided
will
not work.
A special
cable
with a
connector
stamped
in the
center
of the
cable
as well as a
connector
stamped on both
ends
of
the cable will be
required
. This
special
cable
is
shown in
Figure
3.
12
.
[h] SCSI
flat
cable (optional)
[I] SCSI 50-pin connectors
Ul