Pixel
numbers
-54-
When alarm arises, the camera performs output func-
tions according to the setup.
Inputs:
• Input from ALARM IN 1 and ALARM IN 2.
• Input from the built-in VMD (Video Motion Detector)
that detects motion in video by monitoring a speci-
fied area.
Outputs:
• The message "Alarm" is displayed in the upper
right corner of the Main Menu, Camera Control win-
dow and Alarm List.
• The picture files of alarm events are stored in the
camera.
• An e-mail notifies the specified addresses of the
alarm activation with or without a picture file.
• The stored picture files are sent to the FTP server.
• The ALARM OUT terminal on the camera becomes
active.
•A notice of an alarm event is sent to the server
specified in the Panasonic Protocol Setup, using
Panasonic's original protocol.
■ When alarm arises
• The message "Alarm" is displayed in the upper
right corner of the Main Menu, Camera Control win-
dow and Alarm List. The alarm status display may
be delayed for a maximum of half a minute due to
its refresh cycle.
• The pictures related to alarm events are stored in
the camera.
The number of pictures stored differs depending
on the pixel number, picture quality and the num-
ber of pre-alarm pictures stored. The oldest data
will be replaced by new picture data when the
memory capacity is exceeded. The table below
gives the number of pictures available for post-
alarm storage.
When the pre-alarm file is set to 20
When the pre-alarm file is set to none
• E-mail notifications can be sent to a maximum of
four addresses, with or without attached picture
file.
A mail contains: the camera name, time & date of
occurrence, cause of event, and the reference
addresses to the stored pictures as follows.
Number of stored alarm pictures: e.g., 324
URL of the picture: http//(Camera IP address)/
ALMxxxx_00.jpg
Notes:
• "xxxx" stands for the event number, and "00" for the
picture number.
•A picture numbered "00" will be automatically
attached to the mail.
• Enter "39" instead of "00" in the address bar if you
wish to view #40 picture.
• There may be cases where you cannot access the
images notified by the mail when new alarm activa-
tions took place after having sent the mail.
• The alarm picture number is updated during
recording.
• Alarm pictures and recording log are deleted when
the power is turned off.
• The Alarm List number is updated as alarm pic-
tures are to the set number.
ALARM FUNCTIONS
640 x 480
640 x 240
320 x 240
Super fine
113
247
514
160 x 120 514
Picture quality
Fine
165
351
722
722
Normal
210
440
901
901
LOW
242
451
922
922
Pixel
numbers
640 x 480
640 x 240
320 x 240
Super Fine
Picture quality
133
267
534
160 x 120 534
Fine
185
371
742
742
Normal
230
460
921
921
LOW
262
471
942
942