Panasonic WV-CW480S Security Camera User Manual


 
33
6. Synchronization Setting (SYNC)
1. Select a sync mode.
VD2: Multiplexed vertical drive, highest priority
LL: Line-Lock, follows the phase of supplied AC power, 2nd priority
INT: Internal sync, lowest priority
Notes:
Selection is not available when VD2 is added to the camera. Selection from LL is avail-
able when the respective sync is added.
When LL is selected, phase adjustment is required.
2. Line-Lock Vertical Phase Adjustment (V PHASE)
Select LL and press the [SET] button.
Prepare a dual-trace oscilloscope and supply
it with the video output of the camera to be
adjusted and that of the reference camera.
Set the oscilloscope to the vertical rate and
expand the V-sync portion.
Select a proper COARSE phase from 16
steps (22.5 degrees/step) that makes the two
video signals on the oscilloscope the closest.
Select a proper FINE phase so that the two
video signals on the oscilloscope come as
close as possible.
Notes:
Moving the "I" cursor across the +/- end will shift the FINE range.
Press the [LEFT] and [RIGHT] buttons simultaneously to reset the V PHASE to the
default (0 degree).
Keep pressing the [LEFT] and [RIGHT] buttons for a second to move the "I" cursor
faster if necessary.
Spike noise if contained in the AC mains may disturb synchronization of LL.
7. White Balance Setting (WHITE BAL)
Select a mode for WHITE BAL on the CAMERA SETUP menu. The default setting is ATW1.
ATW1: Is automatically adaptable to the colour temperatures of 2 700K - 6 000K.
ATW2: Is automatically adaptable to the use of sodium lamps (2 000K - 6 000K).
AWC: Is automatically adaptable to the colour temperatures of 2 000K - 10 000K.
Notes:
When ATW1 or ATW2 is selected, no further operation is required.
ATW1 and ATW2 do not appear on the setup menu of the system controller.
Select AWC in the following cases: the colour temperature is out of the 2 000K - 6 000K
range, the scene contains mostly high colour temperatures such as blue sky or sunset, or
the scene is dim.
When AWC is selected, the AWC setting is required.
**SYNC**
V PHASE
COARSE 1(1--16)
FINE ...I...128
- +
RET TOP END