Pelco C2950M-E Digital Camera User Manual


 
C2950M-E (8/10) 25
CONFIGURING THE TIME SETTINGS
If the camera is connected to a Dynamic Host Configuration Protocol (DHCP) network that has time server properties configured, the camera will
synchronize automatically with the time server. If the DHCP network’s time server properties are not configured or the network does not have a
time server, you need to configure the DHCP settings manually.
1. Click the System tab.
2. Select General Settings from the drop-down menu.
3. Type the IP address of the time server in the Time Server field. The time server is an external server that uses Network Time Protocol (NTP)
to synchronize the camera date and time settings.
4. Select the Time Zone option. Select the continent and the region that are closest to the camera’s location from the Time Zone drop-down
menus.
NOTE: If your location observes a form of daylight saving time, the system will automatically change the time on the associated dates.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
CUSTOMIZING THE APPEARANCE OF THE TEXT OVERLAY
1. Click the System tab.
2. Select General Settings from the drop-down menu.
3. Set the Text Overlay settings:
Date/Time Overlay: Select Show to display the date and time in the live view overlay. The default setting is Hide.
Camera Name Overlay: Select Show to display the device name in the live view overlay. The default setting is Hide.
4. Select the display position for the overlay from the Position drop-down menu. Selections include Top Right, Top Center, Top Left, Bottom
Right, Bottom Center, and Bottom Left.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.
GENERATING A SYSTEM LOG
1. Click the System tab.
2. Click the Generate System Log button to create a system log that can be used by Pelco Product Support for troubleshooting. Contact Pelco
Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international).
REBOOTING THE CAMERA
1. Click the System tab.
2. Select General Settings from the drop-down menu.
3. Click the Reboot Camera button to restart the camera. Rebooting the camera does not change the configured camera settings.