Planet Technology ICA-650 Digital Camera User Manual


 
Security Features
User Authentication
If desired, the camera access can be restricted to known users. Users will have
to enter their username and password before being able to view the video stream.
Up to 10 users can be entered.
IP filter
The camera access not only can be restricted by username/password, but also
can be limited by the IP range to bring users more security.
Physical Details
1. Alarm cable
The Network Camera provides 8 pins cable to connect with external alarms.
Color definition for installing alarms:
Pin Color Function
1 Black
Alarm Output #2 (NO)
2 Brown
Alarm Output #2 (COM). Max 24VDC, 1A
3 Red
Alarm Output #1 (NO)
4 Orange
Alarm Output #1 (COM)
5 Yellow
Alarm Output #1 (NC). Max 24VDC, 1A
6 Green
Alarm Input #2 (A). Max 24VDC, 12mA
7 Blue
Alarm Input #1/2 (K).
8 Purple
Alarm Input #1 (A). Max 24VDC, 12mA.
3