Recording shot data in the VITC user bits
1 Hold down the ADVANCE button and press the SHIFT button for at
least one second.
This displays the VTR menu.
2 Press the ADVANCE button four times.
3 Press the SHIFT button.
The current setting of VITC UBIT flashes.
4 Press the ADVANCE button until the displayed setting value is 2.
5 Press the SHIFT button twice.
This saves the new setting value.
6 Hold down the ADVANCE button and press the SHIFT button to
exit the VTR menu.
If the new setting is not saved correctly
When you press the SHIFT button in step 5, an indication “5:Exx”
appears. Make the setting once more.