Sony DNW-90WS Camcorder User Manual


 
4-16 Chapter 4 Adjustments and Settings for Recording
4
2 Turn the rotary encoder counterclockwise as seen from the front of
the camera to increase the value, or clockwise to decrease the value,
until the desired frequency appears.
The frequency ranges as follows.
DNW-7: 60.0 Hz to 10156 Hz in 263 steps
DNW-90/90WS: 60.1 Hz to 7000 Hz in 260 steps, and
30.4 Hz to 58.3 Hz in 248 steps
DNW-9WS: 60.1 Hz to 7000 Hz in 260 steps
DNW-7P: 50.0 Hz to 10101 Hz in 312 steps
DNW-90P/90WSP: 50.2 Hz to 9000 Hz in 310 steps, and
25.4 Hz to 48.7 Hz in 295 steps
DNW-9WSP: 50.2 Hz to 9000 Hz in 310 steps
Pressing the MENU CANCEL/PRST/ITEM switch toward the
CANCEL/PRST position returns the setting to the default value,
60.0 Hz (DNW-7)/60.1 Hz (DNW-90/90WS/9WS) or 50.0 Hz
(DNW-7P)/50.2 Hz (DNW-90P/90WSP/9WSP).
When the RM-P9 Remote Control Unit is connected
You can set the shutter speed using the UP/DOWN switch of the RM-P9.
In this case, however, the setting does not appear on the viewfinder
screen.