Sony DNW-90WS Camcorder User Manual


 
Chapter 6 Maintenance 6-5
6
(Continued)
3 Set the iris to automatic adjustment mode and point the camera at
objects of different brightness. Check that the automatic iris
adjustment operates correctly.
4 Set the iris to manual adjustment mode and check that turning the
iris ring adjusts the iris correctly.
5 Hold down the instant auto iris button on the lens and point the
camera at objects of different brightness. Check that the iris ring
turns as the automatic adjustment is made.
6 Set the iris back to automatic adjustment mode, and check the
following points when the GAIN selector is moved from L to M to
H.
For objects of the same brightness, the iris is adjusted to
correspond to the change in setting.
The gain indicator on the viewfinder screen changes to correspond
to the change in setting.
7 If an extender mechanism is incorporated in your lens, put it into the
operative position and check the effect.
6-1-3 Testing the VTR
Perform tests 1 to 6 consecutively in the given order.
1 Testing the tape transport functions
1 Set the VTR SAVE/STBY switch to SAVE and check that the VTR
SAVE indicator in the viewfinder goes on.
2 Set the VTR SAVE/STBY switch to STBY and check that the VTR
SAVE indicator in the viewfinder goes off.