Basic Functions
The initial values are those set at the factory. Settings
for items in Position presets 1 to 6 that will be retained
even when the power to the camera is turned off are
indicated by a “Yes,” those that will be lost are indicated
by an “No.”
When the power is turned on, the settings retained in
POSITION 1 will be called up as the initial settings.
When a CAM_Memory Reset command is sent, or a
choice is made from POSITION 1 to 6 while the
RESET button on the Remote Commander is being
pressed, the settings selected will be used as the
initial settings.
Position preset 1 becomes VISCA command CAM_
Memory memory number 0. Position presets 2
through 6 become VISCA command CAM_Memory
memory numbers 1 through 5.
Mode/Position Initial settings
Position
preset 1
Position
presets 2 to 6
Pan/Tilt Position Home position
Pan/Tilt Limit Position movable-range maximum
Zoom Position Wide end
D-Zoom On/Off
On
Focus Position
Focus Auto/Manual
Auto
Near Limit Setting D000h (30 cm)
AF Sensitivity
Normal
AF Mode
Normal
AF Run Time 5 sec
AF Interval 5 sec
WB Mode
Auto
WB Data (Rgain, Bgain)
One Push WB Data
AE Mode Full Auto
WD On/Off/Auto
Off
Slow Shutter Mode
Manual
Shutter Position 1/30 sec
Iris Position
Gain Position
Bright Position
Exposure Compensation On/Off
Off
Exposure Compensation Amount
±0
BackLight On/Off
Off
Aperture Level
08h
High Resolution Mode On/Off
Off
Picture Effect
Off
ICR On/Off
Off
Auto ICR On/Off
Off
Auto ICR Threshold Level
0Ah
NR Level
3
AE Gain Limit
Low-Illumination Chroma Suppress 2h (Middle)
Color Gain 4h (100%)
Color Hue 7h (0degrees)
Camera ID
0000h
IR_Receive On/Off
On
IR_ReceiveReturn On/Off
Off
Display Information
On
A circle “
” in this column signifies that the data is preserved.
A cross “” signifies that the data IS NOT preserved.
Initial Settings and Position Preset