Sony EVI-H100S Camcorder User Manual


 
26
Command List
As the completion message or error message also has a
socket number, it indicates which command has ended.
Even when two command buffers are being used at any
one time, an EVI-H100S/H100V management
command and some inquiry messages can be executed.
The ACK message is not returned for these commands
and inquiries, and only the completion message of
socket number 0 is returned.
The following command use two sockets during
execution of each command that is sent. The
EVI-H100S/H100V cannot receive other requests
during execution of these commands. In addition,
these commands cannot be executed during operation
of other commands.
SYS_Menu
Command execution cancel
To cancel a command which has already been sent,
send the Cancel command as the next command. To
cancel one of any two commands which have been
sent, use the cancel message.
Cancel Packet Note
Cancel 8X 2Y FF Y = socket number
X = 1 to 7: EVI-H100S/H100V address, Y = socket number
The Command canceled error message will be returned
for this command, but this is not a fault. It indicates
that the command has been canceled.
VISCA Device Setting Command
Before starting control of the EVI-H100S/H100V, be
sure to send the Address command and the IF_Clear
command using the broadcast function.
For VISCA network administration
Address Set
Sets an address of a peripheral device. Use when
initializing the network, and receiving the following
network change message.
Command Reply
Address Set 88 30 01 FF 88 30 0w FF
w = 2 to 7: EVI-H100S/H100V address + 1
Network Change
Sent from the peripheral device to the controller
when a device is removed from or added to the
network. The address must be re-set when this
message is received.
Received Packet
Network Change X0 38 FF
X = 9 to F: EVI-H100S/H100V address + 8
VISCA interface command
IF_Clear
Clears the command buffers in the
EVI-H100S/H100V and cancels the command
currently being executed.
Command Packet Reply Packet Note
IF_Clear 8X 01 00 01FF Y0 50 FF
IF_Clear (broadcast) 88 01 00 01 FF 88 01 00 01 FF
X = 1 to 7: EVI-H100S/H100V address
Y = 9 to F: EVI-H100S/H100V address +8
VISCA interface and inquiry
CAM_VersionInq
Returns information on the VISCA interface.
Inquiry Inquiry Packet Reply Packet Description
CAM_VersionInq 8X 09 00 02 FF Y0 50 GG GG HH HH JJ JJ KK FF GGGG = Vender ID
(0001: Sony)
HHHH = Model ID
050E: EVI-H100V
050F: EVI-H100S
JJJJ = ROM revision
KK = Maximum socket # (02)
X = 1 to 7: EVI-H100S/H100V address (For inquiry packet)
X = 9 to F: EVI-H100S/H100V address +8 (For reply packet)