Sony SNC-VL10N Security Camera User Manual


 
Configuring the Sensor I/O Port — Sensor I/O Setting Page
26
Activity Detection Threshold
Select the sensitivity of activity detection: Low, Mid,
High, Super or Hyper.
The highest sensitivity is given by Hyper, which can
detect the smallest movement.
Showing Pop-up
You can set for displaying “AD” (Activity Detection)
pop-up on the lower-right of the monitor image when an
alarm output is detected.
Select On to show a pop-up, or Off not to show it.
Notes
To show the pop-up on the Firewall Viewer, check on
Show in the Caption menu when you are using the
Firewall Viewer. (See “Caption” on page 10.)
The pop-up is not displayed when the Java Applet
Viewer is used.
Output 1
Set up Output 1 of the Sensor I/O port.
Output 1 can output an alarm triggered by the activity
detection or manually.
Output Status Control
Select Active to keep Output 1 of the Sensor I/O port
usually open and short-circuit it only when an alarm is
output. Select De-Active to keep Output 1 usually
short-circuited and open it only when an alarm is ouput.
Alarm Event-Based Output Activation Function
Select AD to synchronize the output from Output 1 of
the Sensor I/O port with an alarm by the activity
detection, or Manual to output manually by clicking the
Sensor 1 button on the viewer page.
Output Active Duration Time
Type the duration of the output from Output 1 between
1 and 60 seconds.
Lower Half of Sensor I/O Setting
Page
Sensor Input (SI)
Set up the sensor input, that is, the input to the Sensor I/
O port on the rear panel of the camera.
Available Alarm Events
Select Enable if you want to output an alarm when the
input to the Sensor I/O port is detected, or Disable if
you do not want to output an alarm.
Scheduling
Using the boxes below, you can set up to 6 schedules on
which the sensor input works.
Select Enable to enable all the schedules whose check
boxes you have selected, or Disable to disable them.
Scheduling 1 to Scheduling 6
For each schedule, type the time in hours and minutes
when the sensor input starts and ends, and select the
check box(es) of the working days of the week.
To enable each schedule you have set, select the check
box on the left of Scheduling. You can select multiple
schedules.
Note
A schedule across days (ex. 22:00 - 2:00) cannot be set.
Sensor-Type Selection for Input
Select the level of the input which can be used to trigger
an alarm: Low or High.
Input Current Status
Displays the current status of the device connected to the
input of the Sensor I/O port.