Configuring the Sensor I/O Port — Sensor I/O Setting Page
27
Inter-alarm Event Detection Time
Type the duration, between 5 and 60 seconds, during
which the camera can detect the next alarm input.
Showing Pop-up
You can set for displaying “SI” (Sensor Input) pop-up
on the lower-right of the monitor image when an alarm
output is detected.
Select On to show a pop-up, or Off not to show it.
Notes
To show the pop-up on the Firewall Viewer, check on
Show in the Caption menu when you are using the
Firewall Viewer. (See “Caption” on page 10.)
The pop-up is not displayed when the Java Applet
Viewer is used.
Output 2
Set up Output 2 of the Sensor I/O port.
Output 2 can output an alarm triggered by the sensor
input or manually.
Output Status Control
Select Active to keep Output 2 of the Sensor I/O port
usually open and short-circuit it only when an alarm is
output. Select De-Active to keep Output 2 usually
short-circuited and open it only when an alarm is ouput.
Alarm Event-Based Output Activation Function
Select SI to synchronize the output from Output 2 of the
Sensor I/O port with an alarm by the sensor input, or
Manual to output manually by clicking the Sensor 2
button on the viewer page.
Output Active Duration Time
Type the duration of the output from Output 2 between
1 and 60 seconds.
Apply/Cancel/Help
See “Buttons common to every setting page” on page
14.