Changing the setting in 1P SR mode( 1.3. 2)
MODE E.TRG
E.TRG 1P SR
TRG.P
EXP. 30ms
OUT.P OFF
SHUTTER
0.01 ms 0.02 ms 0.4 ms 1 ms 20 ms 30 ms
<MODE = E.TRG E.TRG = 1P SR>
• E.TRG mode
1P SNR, 1P SR, PW SNR, PW SR, RR
• Input trigger pulse setting at 1P SNR and 1P SR
• Exposure time setting at 1P SNR and 1P SR
• Shutter mode MANU, SS, E.TRG, AUTO
Input trigger pulse : positive polarity
Input trigger pulse : negative polarity
Move up down
by pushing
MENU UP, DOWN
Select the desired
value by pushing
DATA UP, DOWN
0.01 ms
step
0.02 ms
step
0.1 ms
step
1 ms
step
• Partial scanning switchPART switch
OFF, 40fps, 42fps, 50fps, 60fps, 70fps, 80fps, 90fps
E.40fps, E.42fps, E.50fps, E.60fps, E.70fps, E.80fps, E.90fps
2 ms
step
Changing the polarity of the input trigger pulse setting(a)
Move the “

” to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
Select either

, , by pushing [DATA UP], [DATA DOWN] buttons.
Changing 1P SR exposure time setting(b)
Move the “

” to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
Select the exposure time by pushing [DATA UP], [DATA DOWN] buttons.

Changing the partial scanning setting(c)
Move the “

” to OUT.P by pushing [MENU UP], [MENU DOWN] buttons.
Select the mode by pushing [DATA UP], [DATA DOWN] buttons.

Move “

” to the current value by pushing [MENU UP], [MENU DOWN] buttons.
Select a desired settings by pushing [DATA UP], [DATA DOWN] buttons.

* The preset value of partial scanning is not displayed, when OUT.P is OFF.