Toshiba IK-TF7P2 Security Camera User Manual


 
30
PWSR(PulsewidthtriggerSYNC-RESET)( 4 )
The trigger input to the CC1 of the DIGITAL terminal develops 1 frame images.
1PulseWidthTriggerSYNC-RESETPictureOutputTiming(4. 1)
Exposure completion
0 to 1H
Negative polarity mode
Positive polarity mode
FVAL
About 1 µs
About 7 µs
Exposure period*
2
Trigger*
1
(Internal VD)
*
3
*
4
RGB data
(video interval image)
LVAL,
DVAL
28H Partial scanning OFF
25H Partial scanning 40fps
27H Partial scanning 42fps
33H Partial scanning 50fps
39H Partial scanning 60fps
43H Partial scanning 70fps
46H Partial scanning 80fps
48H Partial scanning 90fps
*1: External input signal
*2: Exposure time = Trigger pulse width + 6 µs
(Valid trigger pulse width is 2 µs or greater for external trigger shutter operation.)
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchronized to
this and output.
*4: When NR is set to ON, 1H is increased.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trigger, there
will be an effect on the video.
120730c1_IK_TF7P2_EN.indd 30 12.7.30 1:19:04 PM