Magazine
Cleaning the Throat Assembly
The throat assembly photo can be disassembled for
cleaning.
Loosen the three screws photo on the throat
assembly cover photo.
Remove the holder plate photo for the loop
protector.
Pull out the throat assembly cover.
Clean the film running surfaces photo and guide
rollers photo with a brush.
Put the throat assembly cover back in place.
Replace the holder plate for the loop protector and re-
tighten the throat assembly cover with the three screws.
Setting Friction on the Shoulder Magazine
Swing the roller arm photo away from the winding
shaft until it locks in place.
Unscrew the three screws on the transparent tensioning
plate photo.
Remove the plate.
Place a film core on the take-up side.
Place the core adapter photo on the feed-side.
Place the tension measurement device photo on the
core adapter on the feed side.
screws
holder plate guide rollers
running surfaces
Maintenance