3131
Swing the roller arm photo away from the winding
shaft until it locks in place.
Place the film roll next to the magazine, preferably on
a film can.
Insert the film through the upper slit on the magazine
throat assembly from the inside photo.
Do not catch the film.
With your free hand, turn the drive gear counter-
clockwise while carefully pushing the film through until
both perforation holes are picked up simultaneously by
the sprockets.
Keep turning the gear until the film has been transported
through the throat assembly.
Flip up the hinged locking clip on the feed shaft photo.
Place the film roll on the feed shaft, ensuring that the
feed shaft catch engages the slot on the plastic core.
Press down the hinged locking clip on the feed shaft.
By turning the drive gear counter-clockwise, transport
the film further until it reaches to the loop length
marking photo.
Ensure that the film is lying flat against the
outside of the magazine housing.
Without changing the length, thread the film into the
right film channel. Do not catch the film.
roller arm
magazine throat assembly
hinged locking grips
loop length marking
Magazines