Ground Glasses
Interchangeable for various filming formats, same ground glasses as Arriflex 435
Operating Temperature Range
-20°C to +50°C (-4°F to +122°F)
Power Supply
24 V DC
Acceptable voltage range: ....................................................... 20.6…35 V DC
Function Monitoring
Power supply voltage (BAT)
Synchronous running (ASY)
IVS
Weight ....................................................................................approx. 0.35 kg
power consumption ....................................................................approx. 5.4 W
Inputs ............................................................................................................–
Outputs: ........................................2 outputs for composite video or alternatively
1output for composite video
1 Mini-Monitor ouput
Optic ..................................................................................covers silent format
Optic Alignment: ............................................................X, Y rotation and focus
Dimensions
Length with Shoulder Magazine 60/200 without lens: ....450mm .....(17
6
/
8
”)
Width with viewfinder on the left: ..... 230mm (without handgrip) ...........(9 “)
250mm (with handgrip) .......(9
7
/
8
”)
with viewfinder on the right: ............................... 270mm .....(10
5
/
8
“)
Height with grip: .......................................................... 240mm ......(9
4
/
8
”)
without grip: ..................................................... 214mm ......(8
3
/
8
“)
Weight
ARRIFLEX 235 without magazine, without lens
including spherical viewfinder, IVS and Standard Handgrip: .4.1 kg ... (9,03 lbs)