ARRI ARRIFLEX 235 Film Camera User Manual


 
4040
7.2 Exchanging the Ground Glass
By briefly depressing the “PHASE”-button in standby,
the shutter is positioned to protect the mirror surface
from damage as far as possible photo.
Before exchanging the ground glass, switch the
camera’s main switch off and disconnect the camera
from the power supply!
Remove the lens or the protective cap.
Do not touch the mirror surface!
Using the included special forceps, pull the ground glass
photo out of the holder by its tongue photo.
Check that the ground glass to be inserted as well as
the ground glass frame are completely clean.
With the special forceps, push the chosen ground glass
into the holder as far as it will go. The red marker
point must be on the left. A ball catch fixes the ground
glass exactly in the right position.
Check that the ground glass is correctly locked in place.
Note: Cleaning or exchanging the field lens, see
Chapter 13 Maintenance, Cleaning the Field Lens.
tongueground glass
Camera Body