Bosch Appliances VIP X1 Security Camera User Manual


 
EN | 106 Installation and Operating Manual | VIP X1
Operation Bosch Security Systems | 2006-12 | V2.5
Camera control
Control options for peripherals (for example a pan/tilt head or a dome camera)
depend on the type of unit installed and on the configuration of the VIP X1.
If a controllable unit is configured and connected to the VIP X1, the controls for
the unit are displayed next to the video image.
To control a peripheral, click the appropriate controls.
Move the mouse pointer over the video image. Additional options for control-
ling peripherals are displayed with the mouse pointer.
Digital I/O
The alarm icons Input 1 ... Input 4 are for information purposes and indicate the
status of an alarm input: When an alarm is triggered the respective icon lights up
in green. The unit's configuration determines whether the alarm is displayed, as
well as additional details (see Livepage configuration, page 94).
Trigger relay
You can switch a connected unit by means of the relay in the VIP X1 (for exam-
ple a light or a door opener).
To activate this, click the icon for the relay next to the video image. The icon
will be red when the relay is activated.